TSC: The Sensor Connection
EGT high temperature exhaust gas probes Call 248-417-2622

Shop Now!MasterCard ... Visa ... Discover Card

EGT Products & SpecsProduct Manuals & User Info


ANSI
Code
Alloy Combination
Color Coding  USA and Canada  
Maximum Useful
Temperature
Range ++
Maximum
Thermocouple Grade
Temperature
Range
EMF (mV)
Over Max.
Temperature
Range
Standard Limits
of Error**
(above O°C)
Special
Limits of Error**
(above O°C)
International
IEC 584-3
Comments
Environment —
Bare Wire
+ Lead - Lead Thermocouple
Grade
Extension
Grade
J IRON
Fe
(magnetic)
CONSTANTAN
COPPER-NICKEL
Cu-Ni
Thermocouple Grade:
32 to 1382°F
0 to 750°C
Extension Grade:
32 to 392°F
0 to 200°C
–346 to 2193°F
–210 to 1200°C
–8.095 to
69.553
greater of
2.2°C or 0.75%
greater of
1.1°C or 0.4%
Reducing, Vacuum, Inert.
Limited Use in Oxidizing
at High Temperatures.
Not Recommended for
Low Temperatures.
K
NICKELCHROMIUM
Ni-Cr

NICKEL-ALUMINUM
Ni-AI
(magnetic)
Thermocouple Grade:
–328 to 2282°F
–200 to 1250°C
Extension Grade:
32 to 392°F
0 to 200°C
–454 to 2501°F
–270 to 1372°C
–6.458 to
54.886
greater of
2.2°C or 0.75%
greater of
1.1°C or 0.4%
Clean Oxidizing and Inert.
Limited Use in Vacuum or
Reducing. Wide Temperature
Range, Most Popular Calibration
N
NICROSIL
Ni-Cr-Si

NISIL
Ni-Si-Mg
Thermocouple Grade:
–450 to 2372°F
–270 to 1300°C
Extension Grade:
32 to 392°F
0 to 200°C
–450 to 2372°F
–270 to 1300°C
–4.345
to 47.513
greater of
2.2°C or 0.75%
greater of
1.1°C or 0.4%
Alternative to Type K.
More Stable
at High Temps
++ Except as further restricted by temperature limits for T/C diameter and insulation tables that follow.
* Not official symbol or standard designation.
** For controlled initial accuracy below 0°C, ask sales department