•  Welcome Guest
  • Login
  • Register
Call Us  248-636-1515
  • 0 items
  • Total: $0.00
  • View Cart
  • Checkout
[Skip Header and Navigation] [Jump to Main Content]

PERFORMANCE AND RELIABILITY IS OUR BUSINESS

Motorsports

  • EGT Probes
    • Gas
    • Diesel
    • 2-Stroke
    • Extreme Duty Racing
    • All EGT Probes
  • EGT Electronics
    • Meters / Displays
    • Meter Kits
    • Gauges
    • Amplifiers
    • All EGT Electronics
  • EGT Accessories
    • Compression Fittings and Mounting Hardware
    • Connectors
    • Extension Wire
    • Weld Bungs
    • All EGT Accessories
  • CHT Sensors
    • Electronics
    • Accessories
    • All CHT Sensors
  • Gauges / Pyrometers
    • Single Channel
    • Multi-channel
    • All Gauges / Pyrometers
  • Gauge / Pyrometer Kits
    • Single Channel
    • Multi-channel
    • Round Digital Gauge Kits
    • Rectangular Digital Gauge Kits
    • Handheld Digital Gauge Kits
    • Round Analog Gauge Kits
    • Gas Engines Gauge Kits
    • Diesel Engine Gauge Kits
    • Marine Gauge Kits
    • Motor Home Gauge Kits
    • Snowmobile Gauge Kits
    • All Gauge / Pyrometer Kits
  • Belt Temperature
  • Brake Sensors
    • All Brake Sensors
  • Fluid Temperature
    • All Fluid Temperature
  • Linear Travel Sensors
  • Motorsports Tech Notes
    • EGT Tech Notes
      • Why Use our Probes?
      • Thermocouple Wire Color Chart
      • Thermocouple Compatibility List
      • EGT Probe Performance tuning Installation and Information
      • ITS-90 Thermocouple Correction Tables
      • What is a Thermocouple
      • EGT Diesel Engine Installation Information
    • CHT Tech Notes
  • Motorsports FAQ
    • EGT FAQs
    • CHT FAQs
  • Sale Items

Industrial Products

  • Thermocouples
    • Electronics
    • Accessories
    • All Thermocouples
  • RTDs
  • LVDT Position Sensors
    • Spring Loaded
      • AC
      • DC
      • 2-wire 4-20mA
    • Free Core
      • AC
      • DC
      • 2-wire 4-20mA
    • Accessories
    • All LVDT Position Sensors
  • LVDT Electronics
    • Electronics
    • All LVDT Electronics
  • Signal Conditioners
    • DC Input
      • DC Input to Alarms
      • DC Input to DC Output
      • DC Input to Frequency Output
    • Frequency Input
      • Frequency Input to Alarms
      • Frequency Input to DC Output
    • Strain Gauge / Load Cell Input
      • Strain Gauge Input to Alarms
      • Strain Gauge Input to DC Output
    • Temperature Input
      • Thermocouple Input to Alarms
      • Thermocouple Input to DC Output
      • RTD Input to Alarms
      • RTD Input to DC Output
    • All Signal Conditioners
  • Instrumentation
    • Meters / Displays
  • Rotary Sensors
    • Electronics
    • Accessories
    • All Rotary Sensors
  • Linear Position Sensors
  • Pressure Transducers
  • Suco Pressure Switches
  • Cable Assemblies
  • Custom Products
  • Industrial Tech Notes
    • LVDT Tech Notes
    • Signal Conditioner Tech Notes
    • Position Sensors Tech Notes
    • All Industrial Tech Notes
  • Industrial FAQ
    • LVDT FAQs
    • Signal Conditioner FAQs
    • Position Sensors FAQs
    • All Industrial FAQ
  • Sale Products

Find Sensors and Electronics by Application

  • Motorsports
    • Gas Racing
      • Racing Drag / Road/ Circle
      • Motorcycles / Drag / Road / Circle
      • Small Engines
    • Diesel & Bio Fuel
      • Trucks / Towing
      • Heavy Truck / Agricultural
      • Power Gen EGT
    • Marine
      • Marine Diesel
      • Marine Gas
    • Aircraft
      • Small Aircraft Engines
      • Ultralite
    • Commercial
      • Barbecue / Smokers
      • Flu / Heater / Furnaces
      • HVAC
  • Industrial
    • Factory Automation
    • Energy and Power Gen
    • Industrial OEM
    • Hydraulics / Pneumatics
    • Aerospace / Military
    • Civil Engineering

Technical Info

  • Manuals & Datasheets
    • LVDT
      • Catalogs
        • LVDT Short Form Catalogs
        • LVDT Full Detail Catalogs
    • EGT Probes
      • Catalogs
        • EGT Probe Short Form Catalogs
        • EGT Probe Full Detail Catalogs
  • Horsepower Calculators
    • Horsepower
    • Engine Displacement
  • Racing Weather
  • Blogs
    • LVDT Blog
    • EGT Probe Blogs
  • Videos

Corporate Info

  • Sitemap
  • About Us
  • Contact Us
  • Privacy Policy
  • Press Releases
  • Sort by popularity
  • Sort by name
  • Sort by price
Home

Signal Conditioners, Transmitters, Isolators, Converters

Buy online from The Sensor Connection today. We ship Worldwide!

Signal Conditioners, Transmitters, Voltage Isolators, Converters for Industrial, Process, and OEM custom applications

8-Channel Type K Thermocouple Amplifier Signal Conditioner Module with Analog Output

Overview

• Thermocouple Input: Type K (8 independent input channels)
• Linearized Analog Output: -0.5 to 5 VDC (8 independent output channels)
• Supply Voltage: 10 to 32 VDC
• On-board CJC
• Includes detachable signal output/power wiring harness
• Compact Size, only 7.0" x 3.5" x 1.6"

8-Channel Type K Thermocouple Amplifier Signal Conditioner Module Output Side
call
  • Read more

Type K Thermocouple Amplifier Signal Conditioner Module with 0 to 5 VDC Analog Output

Overview

• Thermocouple Input: Type K
• Linearized Analog Output: 0 to 5 VDC
• Supply Voltage: 10 to 32 VDC
• 1 mS Response Time
• Quick Connection via Mini-Thermocouple Plug (included)
• Compact Size, only 2.5" x 2.5" x 0.9"

Type K Thermocouple Amplifier Signal Conditioner Module with 0 to 5 VDC Analog O
call
  • Read more

API 4130GL - Thermocouple to DC Isolated & Linearized Transmitter

• Thermocouple Input Type: J, K, T, E, R, or S
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

API 4130GL Thermocouple Input to DC Transmitter
$429.00
  • Read more

API 4059G - Strain Gauge Bridge/Load Cell to DC Transmitter - Field Configurable - Isolated

• DC Voltage Input: 0-5 mV to 0-400 mV
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Strain Gauge Bridge Excitation: 1 to 10 VDC
• Field-Configurable by User
• Non-Interactive Zero & Span Adjustment Pots

API 4059G Strain Gauge to DC Transmitter Field Configurable
$409.00
  • Read more

APD 1500 & 1520 - Strain Gauge/Load Cell Transducer Input to Setpoint Alarm Trip

• DC Voltage Input: 0-5 mV to 0-2000 mV DC
• Output: (1) SPDT Relay HI alarm (model APD 1500)
• Output: (2) SPDT Relays HI/LO alarm (model APD 1520)
• Strain Gauge Bridge Excitation: 1 to 10 VDC
• Factory Pre-Configured

APD 1500 Strain Gauge Transducer Input to Setpoint Alarm Trip
$359.00
  • Read more

APD 7010 - Frequency to DC Isolated Transmitter

• Frequency Input: 0-25 Hz to 0-20 kHz
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

APD 7010G Frequency to DC Transmitter Module
$409.00
  • Read more

API 7580G - Frequency to DC Isolated Transmitter - Field Configurable

• Frequency Input: 0-100 Hz to 0-30 kHz
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Field-Configurable by User

API 7580G Frequency to DC Transmitter Field Configurable
$409.00
  • Read more

APD 4300 - DC to DC Isolated Transmitter

• DC Voltage Input: 0-100 mV to 0-300 V
• DC Bipolar Voltage Input: +/- 100 mV to +/- 10 V
• DC Current Input 0-1 mA to 900 mA
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

API APD-4300 PLC DC to DC Transmitter Module
$379.00
  • Read more

API 4058G - Strain Gauge Bridge/Load Cell to DC Transmitter - Field Configurable

• DC Voltage Input: 0-5 mV to 0-1200 mV
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Strain Gauge Bridge Excitation: 1 to 10 VDC
• Field-Configurable by User

API 4058G Strain Gauge to DC Transmitter Field Configurable
$359.00
  • Read more

API 1200G - Thermocouple Input to Single Setpoint Alarm Trip

• Thermocouple Input Type: J, K, T, E, R, S,or N
• Output: (1) DPDT Relay
• Factory Pre-Configured

API 1200 Thermocouple Input to Setpoint Alarm Trip
$299.00
  • Read more

APD HV-DC - High Voltage - DC to DC Isolated Transmitter

• DC Voltage Input: 0-100 V to 0-1200 V
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Field-Configurable by User

API APD HV-DC High Voltage DC to DC Isolated Transmitter Field Configurable
$469.00
  • Read more

API 1220G - Thermocouple Input to Dual Setpoint Alarm Trip

• Thermocouple Input Type: J, K, T, E, R, S,or N
• Output: (2) SPDT Relays
• Factory Pre-Configured

API 1220 Thermocouple Input to Setpoint Alarm Trip
$329.00
  • Read more

APD 4393 - DC to DC Isolated Signal Splitter Transmitter

• 1 Input, 2 Independent Outputs
• DC Voltage Input: 0-10 mV to 0-100 V
• DC Bipolar Voltage Input: +/- 50 mV to +/- 10 V
• DC Current Input 0-1 mA to 50 mA
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

APD 4393 - DC to DC Isolated Signal Splitter Transmitter
$559.00
  • Read more

API 7010G - Frequency to DC Isolated Transmitter

• Frequency Input: 0-25 Hz to 0-20 kHz
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

API 7010G Frequency to DC Transmitter Module
$399.00
  • Read more

API 1700G - Frequency Input to Single Setpoint Alarm Trip

• Frequency Input: 0-10 Hz to 0-20 kHz
• Output: (1) DPDT Relay
• Factory Pre-Configured

API-1700G API-1720G
$339.00
  • Read more

API 4380G - DC to DC Isolated Transmitter - Field Configurable

• DC Voltage Input: 0-50 mV to 0-10 V
• DC Bipolar Voltage Input: +/- 50 mV to +/- 10 V
• DC Current Input 0-1 mA to 20 mA
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Field-Configurable by User

API 4380G DC to DC Transmitter Field Configurable
$329.00
  • Read more

APD 7580 - Frequency to DC Isolated Transmitter - Field Configurable

• Frequency Input: 0-100 Hz to 0-30 kHz
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Field-Configurable by User

APD 7580G Frequency to DC Transmitter Field Configurable
$429.00
  • Read more

API 4300G - DC to DC Isolated Transmitter

• DC Voltage Input: 0-100 mV to 0-500 V
• DC Bipolar Voltage Input: +/- 100 mV to +/- 10 V
• DC Current Input 0-1 mA to 900 mA
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

API 4300 DC to DC Transmitter Module
$329.00
  • Read more

API 4385G - DC to DC Isolated Transmitter - Field Configurable - NIZSP

• DC Voltage Input: 0-50 mV to 0-20 V
• DC Bipolar Voltage Input: +/- 50 mV to +/- 10 V
• DC Current Input 0-1 mA to 20 mA
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Field-Configurable by User
• Non-Interactive Zero & Span Adjustment Pots

API 4385G DC to DC Transmitter Field Configurable
$359.00
  • Read more

API 1090G DC Input to Dual Setpoint Alarm Trip - Field Configurable

• 26 field configurable input ranges
• DC Voltage Input: 0-50 mV to +/- 10 V
• DC Current Input: 0-1 mA to 0-20 mA
• Output: (2) SPDT Relays
• Field-Configurable by User

API 1090G DC Input to Alarm Trip Module
$309.00
  • Read more
  • 1
  • 2
  • next ›
  • last »

Harold G. Schaevitz Industries LLC

The Sensor Connection

World Headquarters

42690 Woodward Avenue

Suite 200

Bloomfield Hills, MI 48304

Phone: 248-636-1515  

Fax: 248-636-4969

CORPORATE

  • Sitemap
  • About Us
  • Contact Us
  • Privacy Policy
  • Press Releases

MY ACCOUNT

  • Checkout
  • Login
  • Register
  • View Cart
© Copyright 2021.
All Rights Reserved.
PayPal
Credit Cards
 Network Solutions Seal
website by jhoward.org
[Jump to Top] [Jump to Main Content]